We design and install external and internal lightning protection, earthing and surge protection for multi-storey office buildings, taking rooftop equipment, facades and server rooms into account.

since 2005on the market
1500+completed projects
10 yearswarranty

Trusted by business centres in Kyiv and across Ukraine

Facilities where RAIDEN carried out lightning protection and earthing work.

Pochaina-CenterVolodymyrskyiPyrohovskyiYaroslavskyiContourFRANKEPlatformaIcebergVodafoneWorkit SpacePiraeus BankUNIT CityBusiness centre, Zaporizhzhia

Typical challenges of office buildings and how we solve them

An office complex means height, a flat roof full of building services and a lot of sensitive electronics inside. This is what we check first.

Rooftop equipment

Chillers, air handling units, antennas and advertising structures are exposed to direct lightning strikes.

Solution: separate air terminals and masts with calculated protection zone and separation distance to the equipment.

Facades and height

Glass and metal facades make routing down conductors harder, and height increases the risk of side strikes.

Solution: down conductors within the facade structure or HVC insulated conductors, ring conductors at intervals of height.

Server rooms and IT networks

Surges knock out servers, structured cabling, access control and CCTV.

Solution: staged surge protection (type 1+2 SPDs at the incoming supply, type 2 and protection of data lines).

Equipotential bonding

Steel structures, pipework, lifts and cable routes are at different potentials during a strike.

Solution: a main equipotential bonding bar and connections between all metal parts.

Earthing in dense urban areas

The building is surrounded by car parks, asphalt and utilities, so a classic ring earth is hard to fit.

Solution: deep modular earthing with resistance measurement and a test report.

Requirements and liability

Tenants, insurers and technical supervision require proof that the system complies with standards and works.

Solution: design to DSTU EN 62305, as-built documentation, regular inspection and testing.

How we work with office buildings

From survey to handover with test reports — one team is responsible for the whole cycle.

Survey

A site visit, review of the roof, facades, power supply entry and existing documents.

Design

Protection zone and risk calculation, bill of materials, agreed with you.

Installation

Installation by the RAIDEN team to the agreed design, materials from our shop.

Testing and handover

Earth resistance testing, as-built documentation, 10-year warranty.

Let's discuss your facility

Send us your project, specification or photos of the facility — a manager will check the details and pass them to our engineers. No registration or long forms.

Send your project

Drag files here or choose from your computer
PDF, DWG, DXF, JPG, PNG, XLSX, DOCX, ZIP · up to 5 files · up to 5 MB in total
 
 

Call us

Advice on your facility.

073 361 15 64

Callback

Leave your number and we will call you back during working hours.

Request a callback